LABORATORY REFRIGERATOR

LABORATORY REFRIGERATOR

Laboratory Refrigerators are available in a variety of configurations providing alternatives between cabinet capacity and control capability.

referi

GENERAL FEATURES

Applications include refrigerated storage of Vaccines, Reagents, Cultures, Medicines and Blood samples. Temperature range adjustable from 2.0º C to 8.0ºC with micro controller based temperature controller includes digital temperature display of set value and process value, Forced air circulation for maximum temperature uniformity. Temperature alarm system with adjustable high /low alarm limits includes audible and visual warning.

REFRIGERATION SYSTEM

The cooling is effected by CFC free refrigeration system with split type condensing unit located outside the room. Condensing units are characterised by high-efficiency heat transfer and low power consumption.

CFC
  • CFC free refrigeration with time delay to safe guard the compressor .
  • Inner grooved copper tubes and slit aluminium fins for superior heat transfer.
  • Filter drier for moisture and dirt protection.
  • Safety and control devices for better system protection.
  • Thermally protected and permanently lubricated fan motors.
  • Smaller footprint for ease of handling and installation.

PROGRAMMABLE LOGIC CONTROLLER (PLC) SYSTEM

A programmable logic controller (PLC) is a digital computer used for automation of controlling electromechanical processes, such as control of Temperature, Relative Humidity, Standby systems and event management with less maintenance hence no moving parts.

  • 4.3” HMI with color Display and touch screen.
  • Configurable access for 72 users.
  • Privilege based grouping.
  • Multi level Password protected Human Machine Interface (HMI).
  • Data storage to record set values, process values, date & time with variable time intervals.
  • Display of set value and process value.
  • High speed Ethernet connectivity .
  • incorrect password attempt and user lock.
  • Online data can be printed with date and time stamp.
  • Non operational screen auto logout.
  • Configurable maintenance reminder pop up alarm .
  • Individual Alfa numeric user ID and password.
  • User operation will be recorded and saved in memory.
  • Online and offline Log reports on HMI.
  • Safety cut off for over shoot and under shoot.
  • Programmable alarms with event management.
  • Precise control of temperature by using PID control Action.
  • Data storage capacity up to 200000 readings.
  • Self diagnostic system with error messages
programmable-logic-controller-system

SAFETY FEATURES

  • Miniature circuit breaker to protect electronic components in case of abnormal power supply
  • Audio visual alarm for temperature, humidity variations from set Values
  • Safety includes shut off of boiler and air heaters in case of temperature overshoots or undershoots beyond specified limits with alarms
  • Low water level alarm and power cut off to safeguard the boiler heater
  • Overload load protector to safe guard compressor.
  • Provision for mobile alert via GSM technology for any abnormal conditions
  • Self closing mechanism ensures that the door remains closed
  • Facility to open the door from inside in case of door locked with emergency alarm having switch inside chamber
Technical Specifications
Volume100 Liters200 Liters300 Liters400 Liters600 Liters800 Liters1000 Liters1500 Liters2000 Liters
Temperature range20.0 – 60.0 °C
Accuracy± 0.2 °C
Uniformity± 2.0 °C
Humidity Range40 – 98% RH
Humidity Accuracy± 2 % RH
Uniformity± 3 % RH
Control SystemPLC
No. of tray23444881010
No. of DoorsSingleSingleSingleSingleSingleDoubleDoubleDoubleDouble
Power1500W1750W1750W1750W2000W2500W3500W3500W3500W
Voltage230V AC / 50/60 Hz
Dimensions (W x D x H) in mm and weight (kg)
Internal Dim435x400x600505x400x1005565x450x1205635x530x1205745x670x12051120x600x12001150x670x13001300x890x13001500x1030x1300
Internal Dia580x845x1275650x880x1680710x935x1885780x1010x1880890x1150x19601370x1075x19201400x1145x19201550x1365x19201750x1505x1920
Packing Size707x972x1478777x1007x1883837x1062x2088907x1137x20831017x1277x21631497x1202x21231527x1272x21231677x1492x21231877x1632x2123
Net Weight125150205260285315340365385
Gross Weight180230280330355405430460485

ELFINPRO SOFTWARE

Title 21 CFR Part 11 is the part of Title 21 of the Code of Federal Regulations that establishes the United States Food and Drug Administration (FDA) regulations on electronic records and electronic signatures (ERES). Part 11, as it is commonly called, defines the criteria under which electronic records and electronic signatures are considered trustworthy, reliable, and equivalent to paper records.

  • 21CFR-PART 11 compliance.
  • Browser based software
  • Multiple chamber data acquisition on single software.
  • Reports in Tabular and Graphical form
  • Mean Kinetic Temperature Report.
  • Automatic Back up Provision.
  • Privilege based Group creation
  • Privilege based user creation
  • Trend analysis report
  • Equipment audit trial report
  • User ID with Alfa numeric password protection
  • Multi user environment (LAN)
  • Multiple level password with automatic expiry
  • Electronic signature
  • Separate reports for alarm and events
  • Remote integrations with Control systems
  • Software audit trial report
  • Email, SMS and call alert in case of system failure
    Online and offline trends
programmable-logic-controller-system
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare